Graffunder "F" Fortress Series
Due to the nature of their applications and our philosophy of randomization, the following unit is highly customizable and tailored to the individual end user.
DOOR
| Outer plate: | Minimum 1.5" (38.1mm) lamination of A-36 steel and manganese plate, 4.5" (114.3mm) overall thickness. On fire rated units, door is insulated with 1" (25.4mm) UL approved insulating material. Fire rated units also incorporate high temperature heat seals in strategic areas. |
| Anti-drill barriers: |
Hardened steel ball bearing plate Carbide chip plate Deflector plates |
| Lock: |
One standard from the following:
|
| Re-locking systems: | Randomly positioned, independent live or dead re-lockers, both thermally and mechanically activated. |
BODY
Incorporating ball bearing anti-drill barriers. Punch-resistant bolt work and false barriers are available as options. Outer plates consisting of minimum 1" (25.4mm) A-36 steel. On fire rated units, additional barrier of 1.5" (38.1mm) proprietary high density, cement based composite material enclosed between outer plate and 16ga (1.5mm) interior steel body.